Thank you for your interest in Installing Lift in your DDA / CGHS Flats. This Guide has been prepared to give you all required information at one place .
The decision to retrofit lifts in DDA flats and cooperative group housing societies is cheered by seniors, the disabled, patients and those on the top floors of the old low-rise flats. Our Team is one of the Best Lift Installation Companies In Delhi especially for DDA & CGHS Flats
We shall also Help in Getting NOC from concerned Govt authorities for Lift Installation. According to announcement by DDA, Allottees of DDA flats in denotified areas will now no longer need to approach the housing authority (DDA) for permission for installing lifts and can obtain the same from local bodies (MCD).
That’s Why for smooth procedure of Lift Installation in DDA & CGHS flats, our Engineers can help you in getting everything done on a turn Key basis including NOC for Lift Installation.
The request for seeking NOC for installation of lift and connecting bridge should be submitted by *Proposing Applicants* after obtaining necessary consent from owner(s)/ legal representative(s) of at least 50% of the flats in that staircase (of that block) who shall be beneficiaries upon the installation of Lifts in DDA/CGHS flats.
The consent from ground floor flat owners is desirable but not mandatory for seeking NOC by applicants. Application must be complete with all necessary documents/Affidavits and other pre-requisites for issue of NOC and Lift installation.
Now, to file an application for NOC, all you need is
List of consenting owners ( 50% of upper Floors ) using the common staircase
Proof of ownership of the flat
A certificate by the structural engineer about the safety of the structure
An NOC from the fire department
Layout plan of your site
processing fee by DD of Rs 25,000 approx ( amount may vary depending on MCD guidelines )
A technical feasibility report by our team
MINIMUM LEGAL MANDATORY REQUIREMENT FOR LIFTS OF DDA & CGHS
The Minimum capacity of Lift shall be 4 Pax / 272 Kg
The Lift shall not serve Terrace level .
Pit Less Lift are NOT Allowed . Therefore Lift should have a minimum Pit ( below GF ) of 1500 mm ( 5 feet) ,
The Lift structure shall be independent self supporting without any load on existing walls / Structure of flats . Lift Structure should be designed and installed in such a manner , that water should not enter Pit or Lift well . Structure shall be fully covered / enclosed from all sides .There should not be any gap or open space . Open Type Platform Lifts are not Allowed .
The Lift Control Panel Shall be placed outside the Top Floor Lift Door . Therefore top Floor owners should be aware of this and this control panel should be locked at all times and should be opened only by authorised persons.
Automatic Rescue system during power failure should be provided in Lift with 3 back to back activation without recharging of battery ..
MECHANICAL & ELECTRICAL interlocking of Lift doors must be provided , so that Lift should not run if any of the Door is opened.
Full Length Infrared Door sensor should be provided in the Lift Door to prevent closing of Door on passengers .
Battery operated emergency alarms should be provided in the Lift cabin.
Suitable Emergency Light should be provided in the Lift Cabin .
The designed working Life of Lift should be minimum 15 years..
LIST OF DOCUMENTS for Submitting to MCD
Application form in prescribed proforma
Four sets of plans (one cloth mounted), duly signed by all the proposing member (s) and Architect registered with Council of Architecture under the Architect Act,1972 indicating his/her Name ,address,telephone number clearly showing original construction in blue colour and proposed construction/ construction To be REGULARISED in red colour at a scale not less 1:100 with Part layout plan showing the site under reference and connecting bridge position of the block and its adjoining area.
Certificate of supervision by Architect and LICENSED Engineer (Annexure-B) along with a copy of their valid registration certificate
Proof of ownership documents of flat: Lease Deed/ Conveyance Deed Shall be taken As documents for the proof of ownership. Registered Sale Deed or General power of Attorney/Agreement to sell shall be accepted as the proof of ownership only after the property has been converted into freehold by DDA.
Certificate by proposing member (s) and structural engineer for safety from natural hazard as per the proforma prescribed by Ministry (Annexure-C) Undertaking / affidavit by the proposing member (s) regarding cost of installation Operation and maintenance of lifts.(Annexure-D)
Undertaking on Latter Head of Architect/ Structural Engineer For Structural design as per provision of National Building code. (Annexure-D1 & D2 respectively)
Indemnity Bond from all the proposing applicants indemnifying to keep MCD harmless from any claim which anyone may, at any time institute against the MCD (Annexure E)
Proof of depositing of processing fee
Recommendations of lifts manufacturing agency with regard technical feasibility location of lift Well and connecting bridge
Safety aspect in respect of installation List of all owner/ Legal representatives /Residents using that common staircase giving status as to title (owner/tenant/ Vacant ) and how participating in the application viz :as Proposing member /Secondary member /Un- interested member Undertaking for NOC from CFO lift Inspector & Electrical Distribution Company
Letter from RWA for shifting of services if any.
Scope of Work Involved in this Project
Feasibility study
Submission of technical & commercial offer
Study of technical & commercial offer by residents
Joint meeting between our engineers & residents
Submission of final technical & commercial offer
Release of token advance to start the noc work
Signing of agreement
Collection of all documents / NOC from residents
Drawings by architects / structural engineer
Signing of documents by residents
Preparation of demand draft for fees .
Submission of file in MCD office
Followup & collecting NOC from MCD
Release of advance to start the work
Civil & steel structure work as required -
Breaking of staircase walls / railing
Platform from lift structure to floors,
Digging of earth to make Lift pit , ,
Clearing & disposal of malba & debris
Making double earthing pits
Supply and Fixing 3 phase power cable from GF to Top floor,
Supply & Fixing of switch MCB & ELCB ,
Supply & Fixing exhaust fan & Lighting in lift shaft ,
Supply & Fixing of 2 nos earthing strips from gf to top floor .
Release of payment as per agreed terms
Installation of New 3 Phase power meter
Design & manufacturing of lift
Supply and Installation of Lift
Testing commissioning of lift
Submitting form A for permission from Lift Inspector
Submitting form B For Lift license
Handover of Lift for beneficial usage
Warranty & AMC services
Renewal of Lift License
How Much Budget Is required ?
The Installation of Lift in DDA/ CGHS flats is quite a tedious & Lengthy process . It involves a lot of effort by a team of Lift Engineers ,Structure Engineer, Architect & Civil structure Contractors... If you wish to carry out this work on turnkey basis, then
you need to allocate a budget of 15 To 18 Lakhs ( GST shall be extra as applicable ) depending upon type of Lift and scope of works . . We shall submit the detailed break up and scope of works with technical and commercial offers . Kindly go through the brief description of scope of work as given in this guide.
Trap of Low Price - कृपया कम कीमतों के झांसे में न आएं
While it is good to compare cost, please remember that Cheapest does not mean Safe & Durable . There are many ways to reduce prices by compromising Safety and Durability . While you wish to spend the lowest budget to purchase a Lift , your budget should be enough to buy a durable Safe Lift . You must spend as required to purchase the right product .Please do not fall trap for a low price.
A Lift must be installed by a professional Elevator company. Please ensure before buying that Lift company has the necessary skills and knowledge. There are many local assemblers, who sell products at low cheap prices . कृपया कम कीमतों के झांसे में न आएं I Please do not fall into the trap of low prices. This can be risky besides losing your investment. These jugad products may not meet the required BIS Safety code IS 14665. Many of local company are fly by night operators . They do not have any infrastructure . Many a times, they can not sustain for long . They do not have any system and process .
The installation of a Lift can be expensive & time consuming, so it is important to consider the cost of the Lift, as well as the cost of getting a Civil Contractor or Electrical and other contractors involved. Additionally, some Lifts require a lot of space which might not be able to fit in some homes. First, you should know what type of Lift you need and its specifications.
You should also know about the costs and benefits so that you can make an informed decision. Most of the bigger MNC Lift Suppliers will install their proprietary equipment at a discounted rate, knowing well that they shall be locking you into their proprietary equipment for years to come. You may also be faced with extremely high fees they charge for maintenance and servicing of their equipment.. Many of Bigger Lifts suppliers have made their Business Strategy to reduce the life cycle of their equipment over the years. While in the good Old days, they used to make Elevator equipment and parts that used to last 20 to 30 years, which now has been reduced.Obviously, The repair costs are also considerably higher. You may be locked with this equipment and you can not change your service provider, Mainly because spare parts shall not be available in the open market and The worst is the self-locking kind of software which shall stop the Lift after a certain predetermined time, forcing to take AMC at the exorbitant price from MNC only .
100% made in India Global Lifts are available in Market now . We have all kind of Lift suitable for DDA & CGHS flats . We also provide maintenance & repair services for your budget & Requirements .
Description of Proposed Lift
Passenger Lift with full Passenger Safety having Max Capacity & speed as 6 Persons , 408 kgs @1.00 mps. BUILT WITH A 30% Power saving AC Variable Voltage Variable Frequency drive
LATEST Microprocessor based control with self diagnostic & running in Simplex down collective mode .
This lift shall have Max Floor / Stops / Opening G+3, 4 stops / 4 opening & Max Travel 10 meters approx ( 30 feet approx ) with OUTER Structure Height of Maximum 15 meters ( 45 feet approx) . designed for Indoor Environment application.
Main MOTOR & machine shall be PMSM GEAR-LESS Traction Machine or geared traction as per site requirement
Car & Door Design shall be Stainless Steel in hairline finish with suitable False ceiling, spot LED Lighting & pressure fan & Anti skid PVC flooring. protected by FULLY AUTOMATIC Car & Landing OPENING doors
Lift Sizes may vary at the time of FINALISATION of drawings, THE PROPOSED LIFT SIZES MAY BE having maximum Car size 900 mm (W) x 1200 mm (D) x 2200 mm (H) with Door OPENING OF 700 mm ( W ) x 2000 mm (H) .
Proposed Lift Structure space may be 1850 mm (W) x 1850 mm (D)- 6 feet x 6 feet . This Space shall be decided after feasibility study and available space at site . THIS HALL REQUIRE Pit depth & Overhead 1600 mm & 4500 mm.
Required Power Supply - 415 volts, 50 Hz, 3 Ph , 4 wire with double earthing & 1Ph 230 volts, 50 hz,
Sizes can be easily customised as per space available at site
Proposed TECHNICAL SPECIFICATIONS
Your Benefit & advantage - Very Long Life & Zero maintenance . Highest Safety factor with Smooth & Jerk Free Run -
our Lift shall be equipped with best of Features, Benefits & advantages
Machine & Motor -100% made in India -Warranty - 4 Years for Motor
Green Technology with a Duty Cycle -S5-40%, 24 Pole PMSM Gear-Less Motor Having F Class Insulation with Very High duty and High Torque , Equipped with Imported Heidenhain ERN 1387 Incremental rotary Encoder with 2048 PPR Sin-cos Encoder with integral bearing for mounting by stator coupling with Line count of 2048 for Best safe & accurate performance . Highest Degree of protection: IP 41 . Insulation Class-H which Can work in High Operating temperature: -40/+120 °C with Main Sheave Pulley Dia - 320 mm as per Safety Code IS 14665. Starts Per Hour-240 ST/H , Pulley Groove Type- Undercut 'U' and Roping Style -2:1.
Proposed TECHNICAL SPECIFICATIONS
Control Drive & Electrical System - 100% made in India. Your Lift shall be equipped with best of Features. Your Benefit & advantage - Very Long Life & Zero maintenance . High Safety factor with Smooth & Jerk Free Run
Built in ACV3F Drive with Micro controller Based control with Self Fault diagnostic having Power saving Auto Light cut off when Lift not in use . Digital Floor Indicators on all Floors . Power saving with LED Lights Good Ventilation Airflow . Auto Rescue Device Built In . Braille marked Buttons (available on demand). Voice Floor Announcements Door open Button & Door Close Button . Adjustable Door Speed
Mechanical System 100% made in India
Heavy Steel Gauge Car Guide T Rail with Special High Tensile Elevator Rope with Wedge Type Rope attachments for extra Fail Proof Safety
Cabin Design 100% made in India
Space Efficient with Rational mechanical Layout with Attractive cabin Design with Laser Cut False Ceiling having Beautiful Car operating panels (micro push) and Anti Skid Flooring (custom Marble flooring available at extra cost) along with Mirror & Handrail in Lift Cabin .
Safety Devices - 100% made in India
Your Lift shall be equipped with best of Features, Benefits & advantages
ARD To Bring the Lift to nearest Floor In Power Failure
Door Safety Electrical Interlocking +To prevent Lift to run without door fully closed
Door Safety Mechanical Interlocking +To prevent Lift Door to open at other floors
Free Fall Protection safety Gear to Stop the Lift in case of free fall
Over Speed Governor prevent the Lift from over speeding
Emergency Stop Switch in cabin +stop the Lift in case of emergency
Emergency Alarm + alarm in case of power failure / or similar situation
Auto Light / Fan cut off +save power consumption when Lift is not in Use
Registration Light in buttons +prevent frequent pressing of buttons to register call
Door Safety Sensor to prevent closing of doors when someone between doors
Final limit Switches to prevent over travel & to cut of power in case of over travel
Pit Safety Switch to prevent moving of Lift car when someone is in Pit
Car Top Safety Switch to prevent moving of Lift car when some one in at car top
Inspection switch to run the Lift in slow speed during Inspection run
Dual Arm Brake Heavy duty Brake to hold 125% of Capacity
Reverse Phase Protection Prevent running of Lift in wrong direction
Safety Operated Switch Power Cut of Tripping during Free Fall .
Slow Down Limit Switch on Terminal floor Forced slow down in case of normal failure
Closed loop Operation Encoder is provided to monitor control for speed of motor
Car self-levelling device Automatic Self levelling devices are built in
Terminal Buffers Terminal HD Spring buffers in Pit below car Counterweight
Click here to check Official Web site
What is the procedure to obtain permission for erection of the lift?
After completion of the building structure , where the lift is proposed to be installed, the owner / occupier of the building has to submit the following documents for seeking permission to erect the Lift. Application on a prescribed form 'A' along with the The drawings of the Lift installation.On receipt of the application, the Inspector of Lift inspect the site and issue permission to erect the lift, if the site is found suitable and meeting the requirements set out in Lift Act & Rules made there under. Under the provisions of Lift Act/Rules, every passenger lift installed in any building except the buildings maintained by Public Works Department and M.E.S., are required to obtain license for working of the Lift.
How to obtain a licence for working on the Lift ?
After completion of the installation of the lift, the owner/occupier of the building has to intimate on Form-B marked as Annexure-I along with the prescribed inspection fee to Inspector of Lifts, NCT of Delhi. On receipt of Form-B, the inspector of Lifts inspects the lift and its installation and if satisfied that the provisions/specification prescribed in the Act/Rules and relevant Indian Standard Code are complied with, issue license for working of the lift in form 'C' marked as Annexure 'J'. The purpose of lift inspection is to ensure the compliance of safety measures prescribed in the Act/Rules and various Indian Standard Codes.